Search results for "width [Lambda(1405)]"

showing 10 items of 330 documents

Phosphorous doping and drawing effects on the Raman spectroscopic properties of O=P bond in silica-based fiber and preform.

2012

International audience; We report an experimental study of the doping and drawing effects on the Raman activities of phosphorus (P)-doped silica-based optical fiber and its related preform. Our data reveal a high sensitivity level in the full width at half maximum value of the 1330 cm−1 (O = P) Raman band to the P-doping level. Its increase with the P doping level does not clash with an increase in the disorder of the O = P surrendering matrix. In addition, we observe that in the central core region of the sample (higher doping level), the drawing process decreases the relative band amplitude. We tentatively suggest that this phenomenon is due to the change in the first derivate of the bond…

(060.2310) Fiber optics; (300.6450) Spectroscopy Raman; (160.2750) Glass and other amorphous materials; (060.2280) Fiber design and fabrication; (060.2290) Fiber materials.inorganic chemicalsMaterials scienceOptical fiberAnalytical chemistryChemical vapor depositionlaw.inventionCondensed Matter::Materials Sciencesymbols.namesakeOpticslawPolarizabilityCondensed Matter::SuperconductivityFiber[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryDopingtechnology industry and agricultureFiber optics Spectroscopy Raman Glass and other amorphous materials Fiber design and fabrication Fiber materialsElectronic Optical and Magnetic MaterialsFull width at half maximumsymbolsbusinessRaman spectroscopyhuman activitiesRaman scattering
researchProduct

Comparison of Single Event Transients Generated at Four Pulsed-Laser Test Facilities-NRL, IMS, EADS, JPL

2012

Four pulsed-laser single-event effects systems, differing in wavelength and pulse width, were used to generate single event transients in a large-area silicon photodiode and an operational amplifier (LM124) to determine how transient amplitude and charge collection varied among the different systems. The optical wavelength and the focused spot size are the primary factors influencing the resultant charge density profile. In the large-area photodiode the transients can be distorted by high charge-injection densities that occur for tightly focused, higher energy optical pulses. When the incident laser-pulse energies are corrected for reflection losses and photon efficiency, with collection de…

010302 applied physicsNuclear and High Energy PhysicsMaterials sciencePhotonta114010308 nuclear & particles physicsbusiness.industryTransistorLaser01 natural sciences7. Clean energy[SPI.TRON]Engineering Sciences [physics]/Electronicslaw.inventionPhotodiodeSemiconductor laser theoryWavelengthOpticsNuclear Energy and Engineeringlaw0103 physical sciencesOptoelectronicsTransient (oscillation)Electrical and Electronic EngineeringbusinessPulse-width modulationIEEE Transactions on Nuclear Science
researchProduct

Rough Set Theory for Optimization of Packet Management Mechanism in IP Routers

2020

Bandwidth and consequently optimum overall efficiency of network system relies greatly on mechanism of packet management in IP routers. Our research objective is to implement rough set theory to minimizing number of the network system attributes responsible for decision making in selection of those packets, which improve its transmission. Such an approach is called priority queuing system model, as we assign priority to the packets selected, following rough set theory. Regardless of the file format, for all the routers, packets are transmitted in sequence one-by-one. Nonetheless, quality of streaming data largely depends on how much the packet loss is minimized, or eliminated at all, if pos…

021103 operations researchNetwork packetComputer sciencebusiness.industryComputerSystemsOrganization_COMPUTER-COMMUNICATIONNETWORKSBandwidth (signal processing)0211 other engineering and technologies02 engineering and technologySystem modelIPv6Set (abstract data type)Transmission (telecommunications)Packet lossRough setbusinessComputer network
researchProduct

X-ray response of CdZnTe detectors grown by the vertical Bridgman technique: Energy, temperature and high flux effects

2016

Abstract Nowadays, CdZnTe (CZT) is one of the key materials for the development of room temperature X-ray and gamma ray detectors and great efforts have been made on both the device and the crystal growth technologies. In this work, we present the results of spectroscopic investigations on new boron oxide encapsulated vertical Bridgman (B-VB) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Several detectors, with the same electrode layout (gold electroless contacts) and different thicknesses (1 and 2.5 mm), were realized: the cathode is a planar electrode covering the detector surface (4.1×4.1 mm2), while the anode is a central electrode (2×2 mm2) surrounded by a guard-rin…

0301 basic medicine030103 biophysicsNuclear and High Energy PhysicsHigh fluxDigital pulse shape analysi01 natural sciencesBoron oxide encapsulated vertical Bridgmanlaw.invention03 medical and health scienceslaw0103 physical sciencesPolarization (electrochemistry)InstrumentationPhysicsX-ray and gamma ray detectors010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorEnergy-resolved photon counting detectorSettore FIS/01 - Fisica SperimentaleDetectorGamma raySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CathodePhoton countingAnodeFull width at half maximumElectrodeEnergy-resolved photon counting detectorsOptoelectronicsDigital pulse shape analysisbusinessNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Improved electroless platinum contacts on CdZnTe X- and γ-rays detectors

2020

AbstractPlatinum is a promising candidate for the realization of blocking electrical contacts on cadmium-zinc-telluride (CdZnTe or CZT) radiation detectors. However, the poor mechanical adhesion of this metal often shortens the lifetime of the final device. In this work, a simple and effective procedure to obtain robust platinum contacts by electroless deposition is presented. Microscopical analysis revealed the final thickness and composition of the contact layer and its adhesion to the bulk crystal. The blocking nature of the Pt-CdZnTe junction, essential to obtain low noise devices, was confirmed by current–voltage measurements. The planar Pt-CdZnTe-Pt detectors showed good room temperat…

0301 basic medicineMaterials for devicesMaterials sciencechemistry.chemical_elementlcsh:MedicineElectronCZT detectorELECTRIC-FIELD PROFILE;TRANSIENT-CURRENT;TRANSPORT-PROPERTIESPULSE-SHAPE;CDTE;PERFORMANCE;RESISTIVITY;DEPOSITION;BULKParticle detectorArticle03 medical and health sciences0302 clinical medicinePlanarlcsh:ScienceMultidisciplinarybusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorlcsh:RCarrier lifetimeX-ray and gamma ray detectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Electrical contactsMaterials scienceFull width at half maximum030104 developmental biologychemistrysemiconductor detectorOptoelectronicslcsh:QbusinessPlatinum030217 neurology & neurosurgeryScientific Reports
researchProduct

Transition-Edge Sensors for Particle Induced X-ray Emission Measurements

2013

In this paper we present a new measurement setup, where a transitionedge sensor detector array is used to detect X-rays in particle induced X-ray emission measurements with a 2 MeV proton beam. Transition-edge sensors offer orders of magnitude improvement in energy resolution compared to conventional silicon or germanium detectors, making it possible to recognize spectral lines in materials analysis that have previously been impossible to resolve, and to get chemical information from the elements. Our sensors are cooled to the operation temperature (65 mK) with a cryogen-free adiabatic demagnetization refrigerator, which houses a specially designed X-ray snout that has a vacuum tight window…

Accelerator Physics (physics.acc-ph)Physics - Instrumentation and DetectorsMaterials scienceProtonPhysics::Instrumentation and DetectorsOrders of magnitude (temperature)FOS: Physical scienceschemistry.chemical_elementGermaniumRadiationSpectral lineOpticsGeneral Materials Scienceparticle induced X-ray emission (PIXE)Emission spectrumbusiness.industryDetectorInstrumentation and Detectors (physics.ins-det)transition-edge sensorCondensed Matter PhysicsAtomic and Molecular Physics and OpticsFull width at half maximumchemistryPhysics - Accelerator PhysicsbusinessTESJournal of Low Temperature Physics
researchProduct

A Metaheuristic Bandwidth Allocation Scheme for FiWi Networks Using Ant Colony Optimization

2015

Optical-wireless access networks constitute a quite attractive solution to meet the ever-increasing bandwidth requirements of end-users, offering significant benefits such as ubiquitous coverage in the wireless domain and huge bandwidth in the optical domain. However, converging optical and wireless networking technologies, with Passive Optical Networks (PONs) and 4G wireless standards, such as the Worldwide Interoperability for Microwave Access (WiMAX) and the Long Term Evolution (LTE), entails major challenges that need to be addressed. In this context, designing an efficient and fair bandwidth distribution with Quality of Service (QoS) support is a difficult task due to the interdependen…

Access networkDynamic bandwidth allocationWireless networkbusiness.industryComputer scienceSettore ING-INF/03 - TelecomunicazioniComputerSystemsOrganization_COMPUTER-COMMUNICATIONNETWORKSWiMAXPassive optical networkBandwidth allocationComputer Networks and CommunicationAutomotive EngineeringBandwidth (computing)Radio resource managementbusinessComputer network
researchProduct

Monocyte distribution width (MDW) as a screening tool for sepsis in the Emergency Department

2020

Abstract Objectives The diagnosis of sepsis in the Emergency Department (ED) is challenging and a reliable biomarker is needed. The current study aimed to evaluate the diagnostic accuracy of monocyte distribution width (MDW) for the early identification of sepsis in the ED. Methods We performed a large observational study including consecutive adult patients (≥18 years of age) presenting to the ED between September and November 2019, with an order for complete blood count (CBC) evaluation. A total of 2,215 patients were enrolled and classified based on Sepsis-2 criteria as the control group (1,855), infection group (172), Systemic Inflammatory Response Syndrome (SIRS) group (100), and sepsi…

AdultMalemedicine.medical_specialtyClinical BiochemistryEmergency Department (ED)030204 cardiovascular system & hematologyMonocytesCohort StudiesSepsis03 medical and health sciences0302 clinical medicineSepsisInternal medicinemedicineHumansDistribution (pharmacology)sepsis.Agedmedicine.diagnostic_testbusiness.industryscreeningMonocyteBiochemistry (medical)monocyte distribution width (MDW)Complete blood countGeneral MedicineEmergency departmentMiddle Agedmedicine.diseaseinfectionSystemic inflammatory response syndromemedicine.anatomical_structureROC CurveArea Under Curve030220 oncology & carcinogenesismonocyteBiomarker (medicine)FemaleObservational studyEmergency Service HospitalbusinessBiomarkersClinical Chemistry and Laboratory Medicine (CCLM)
researchProduct

No short-term effects of digital mobile radio telephone on the awake human electroencephalogram

1997

A recent study reported the results of an exploratory study of alterations of the quantitative sleep profile due to the effects of a digital mobile radio telephone. Rapid eye movement (REM) was suppressed, and the spectral power density in the 8–13 Hz frequency range during REM sleep was altered. The aim of the present study was to illuminate the influence of digital mobile radio telephone on the awake electroencephalogram (EEG) of healthy subjects. For this purpose, we investigated 34 male subjects in a single-blind cross-over design experiment by measuring spontaneous EEGs under closed-eyes condition from scalp positions C3 and C4 and comparing the effects of an active (0.05 mW/cm2) and a…

AdultMalemedicine.medical_specialtyRadio WavesPhysiologyComputer scienceBiophysicsAudiologyElectroencephalographyDigital mobile radioGSMmedicineHumansRadiotelephoneSingle-Blind MethodRadiology Nuclear Medicine and imagingWakefulnessBioelectromagneticsCross-Over Studiesmedicine.diagnostic_testEye movementElectroencephalographySignal Processing Computer-AssistedGeneral MedicineTelephoneSleep (system call)Pulse-width modulationBioelectromagnetics
researchProduct

Algebraic real-time algorithm for B-Spline sinusoidal pulse width modulation in three phase voltage source inverters.

2008

In this paper a novel algebraic real-time algorithm for implementation of sinusoidal pulse width modulation (SPWM) based on B-spline carriers is introduced and discussed. B-spline functions are used as carrier signals with the aim to to reduce harmonic content of the three phase inverter output voltage. This algorithm eliminates the problem of B-spline recursive evaluation with convolution integrals or convolution sums in digital counterpart. The pulse pattern synthesis is made with the help pre-calculated duty cycle expressions. In this way the carrier signals have not to be really synthesized, hence the hardware and the whole inverter control system becomes cheaper, more reliable and affo…

Amplitude modulationTotal harmonic distortionThree-phaseControl theoryDuty cycleInverterVoltage sourcePower factorPulse-width modulationMathematics2008 IEEE International Symposium on Industrial Electronics
researchProduct